ABS Server-Reserved-009 rack server dual EPYC 9355 512GB DDR5 15.36TB
Dual 32-core EPYC 9355 CPUs, 512 GB DDR5-6400 ECC memory and a 15.36 TB U.2 drive in a 4U chassis with 1600 W Titanium power
- Dual 32-core EPYC 9355 CPUs deliver 64 threads for heavy compute
- 512 GB DDR5-6400 ECC memory protects data integrity at speed
- 36 TB Kingston DC3000ME U.2 SSD provides high-capacity enterprise storage
- 1600 W 80 Plus Titanium PSU ensures efficient power delivery
- Rosewill THOR NAS Pro chassis supports up to 8 hot-swap 3.5" drives
Dual 32-core EPYC 9355 server
This 4U rack server ships with two AMD EPYC 9355 processors, each running at 3.55 GHz with 32 cores and 64 threads. A 1600 W 80 Plus Titanium power supply feeds the platform. The GIGABYTE MZ73-LM2 motherboard includes a TPM 2.0 module and fits the Rosewill THOR NAS Pro chassis that supports up to eight 3.5-inch hot-swap bays.
Suits compute-dense workloads needing high memory
Organisations running virtualisation clusters, database instances or rendering farms can use the 512 GB DDR5-6400 ECC registered memory. Buyers who require more storage than the single 15.36 TB U.2 drive provides should look at configurations with additional drive bays populated.
512 GB DDR5-6400 ECC registered RDIMM
The memory subsystem is the specification that determines whether this system matches the workload. Capacity and error-corrected DDR5 speed must align with the application requirements before purchase.
How it compares
Measured against everything we stock in Rack & Tower Servers, at today’s prices. Recalculated every night.
- Price $37,860.99
- Pricier than about 91% of the 17,640 comparable items (median $1,910.99).
New to this? Buying server hardware with crypto — what to check, what it costs to pay, and what is never asked for.
Specifications
| Size & build | |
|---|---|
| Shipping weight | 32.21 kg |
| Package size | 635 × 622 × 330 mm |
Questions about this item
What chassis dimensions and drive-bay layout does the Rosewill THOR NAS Pro use for the 15.36 TB U.2 SSD?
The full-tower chassis supports up to eight 3.5" hot-swap bays; the 2.5" U.2 SSD mounts in one of those bays using a carrier or adapter.
What is the correct orientation for the two SP5 3U active heatsinks on the GIGABYTE MZ73-LM2 motherboard?
Align each heatsink with the SP5 socket key, apply the supplied thermal interface material, then secure the four captive screws in a diagonal pattern to seat the 280 W EPYC 9355 processors evenly.
When should the 512 GB DDR5-6400 ECC RDIMMs and the Kingston DC3000ME 15.36 TB U.2 drive be replaced?
Replace memory modules if ECC correctable-error counts rise sharply or UEFI logs report uncorrectable errors; retire the SSD when SMART media-wear indicator approaches the rated endurance limit.
More in Rack & Tower Servers
Similar items
DELL PowerEdge R760 2U rack server 2x Xeon Silver 4410Y 2.0GHz 1TB DDR5 H965i 16x 2.5" 5720 iDRAC9 2x 1400W
- 2U
- Rack
DELL PowerEdge MX760C rack server 2x Gold 6438Y+ 2.0GHz 32C 512GB DDR4 6x 1.92TB SATA SSD
- Intel
- Half Width Blade
DELL PowerEdge R760 16-Bay 2U Server 2x Xeon Gold 6426Y 1TB DDR5 H965i 5720 iDRAC9 Datacenter 2x 1400W PSU
- 2U
- Rack