Lian Li UNI Fan TL LCD Wireless 140mm Reverse Blade case fan 14RTLLCD1W1B
- 140 mm
- Fluid Dynamic
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Axial case fan measuring 172 x 150 x 38 mm runs on 230 V AC at 50/60 Hz, drawing 0.26 A for 36 W at 3100 rpm and delivering 5.7 m³/min airflow at 58 dB(A)
The ROYAL UT797C-TP is an axial case fan built for 230 VAC mains supply at 50 or 60 Hz. Its 172 by 150 by 38 mm frame fits standard industrial cut-outs in medical devices, rail vehicles and electronic enclosures. The unit draws 0.26 A at 50 Hz and 0.22 A at 60 Hz for direct wiring into AC panels.
At 50 Hz the fan runs at 2650 r/min delivering 4.8 m³/min airflow at 104 Pa static pressure with 55 dB(A) noise. At 60 Hz speed rises to 3100 r/min raising airflow to 5.7 m³/min and pressure to 107 Pa while noise reaches 58 dB(A). Power consumption shifts from 36 W to 31 W across the two line frequencies.
Because the motor runs directly from 230 VAC there is no PWM or voltage speed control built in. The two operating points are fixed by the supply frequency so airflow cannot be tuned to thermal load. The 38 mm depth requires adequate panel clearance and the 55 to 58 dB(A) output may be too loud for quiet office or home environments.
Measured against everything we stock in PC Cooling Fans, at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
No published specifications for this item yet.
Sleeve bearings typically require relubrication or replacement once the oil film degrades; plan service intervals based on the 55 dB(A) baseline noise rising noticeably.
Bearing temperature rise usually becomes the limiting factor before airflow drops below the rated 4.8 m³/min at 104 Pa static pressure.
Expect 36 W of waste heat and a steady 55 dB(A) at 50 Hz, rising to 58 dB(A) and 31 W at 60 Hz.
More in PC Cooling Fans
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?