MINUTEMAN ED6KTF 6000VA UPS 208V/240V 237 lbs
A true on-line double-conversion UPS delivering 6000VA with configurable 208VAC or 240VAC output, an isolation transformer for 120VAC support, and extended runtime via external battery packs
- Voltage version208 V/240 V
- Volt-ampere rating6000 VA
- Voltage output120/208/220/230/240VAC
- Replacement batteryB00007
- Surge protection rating972 Joules
- Product dimensions32.54 in × 9.8 in × 22.1 in
Model ED6KTF
- ED1000RTXL2U$854.99
- ED1000RTXL2UNC$1,263.99
- ED10KRT$4,246.99
- ED10KRT-10KTF2$6,827.99
- ED10KRT-3KTF$5,935.99
- ED10KRT-5KTF$5,929.99
- ED10KRT-6KTF2$6,421.99
- ED10KRT-8KTF2$8,157.99
- ED10KTF$3,388.99
- ED2000RTXL2U$1,437.99
- ED2000RTXL2UNC$1,788.99
- ED6KTF$2,805.99
Show 16 more
- ED3000RTXL2U$2,317.99
- ED3000RTXL2UNC$2,333.99
- ED-3KTF$1,547.99
- ED5KRT$3,005.99
- ED5KRT-3KTF$4,764.99
- ED5KRT-5KTF$4,516.99
- ED-5KTF$2,201.99
- ED6KRT$3,275.99
- ED6KRT-3KTF$4,676.99
- ED6KRT-5KTF$4,895.99
- ED6KRT-6KTF2$5,690.99
- ED8KRT$4,292.99
- ED8KRT-3KTF$4,923.99
- ED8KRT-5KTF$5,900.99
- ED8KRT-6KTF2$6,173.99
- ED8KRT-8KTF2$7,395.99
- True on-line double-conversion topology delivers clean 6000VA power
- 0 output power factor supports full 6000W load without derating
- Configurable 208VAC or 240VAC output matches facility voltage
- Output isolation transformer enables 120VAC full-load support
- Extended runtime available through external battery packs
True On-Line Double-Conversion UPS
The MINUTEMAN ED6KTF is a 6000VA true on-line, double-conversion uninterruptible power supply designed for environments requiring continuous, conditioned power. It accepts a hardwired 208V or 240V input and delivers configurable output voltages including 120, 208, 220, 230 and 240VAC. The unit weighs 237 lbs and measures 32.54 by 9.8 by 22.1 inches.
Output Isolation Transformer and Bypass
An internal output isolation transformer enables full-load 120VAC support across the configurable voltage range. Automatic internal bypass and a maintenance bypass allow service continuity without interrupting connected equipment. The replaceable battery uses part number B00007 and runtime can be extended through external battery packs.
Surge Rating and Power Factor Limits
Surge protection is rated at 972 Joules for the installation. The unit operates at a 1.0 output power factor, meaning the 6000VA rating equals 6000W of real power capacity. Buyers needing higher surge energy absorption or a lower input voltage than 208VAC should verify compatibility before installation.
How it compares
Measured against everything we stock in Uninterruptible Power Supplies (UPS), at today’s prices. Recalculated every night.
- Price $2,805.99
- Pricier than about 82% of the 1,153 comparable items (median $948.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | MINUTEMAN |
| Product line | ENDEAVOR |
| Model name | ED6KTF |
| Power | |
| Voltage version | 208 V/240 V |
| Volt-ampere rating | 6000 VA |
| Voltage output | 120/208/220/230/240VAC |
| Replacement battery | B00007 |
| Surge protection rating | 972 Joules |
| Size & build | |
| Product dimensions | 32.54 in × 9.8 in × 22.1 in |
| Product weight | 237 lb (108 kg) |
| Shipping weight | 107.50 kg |
| Package size | 826 × 561 × 249 mm |
Other versions of this model
5 more in the same range
MINUTEMAN ED3000RTXL2U 3000VA 2700W UPS 2U Tower/Rack/Wall Mountable
- 120 V
- 0-160VAC
MINUTEMAN ED5KRT UPS 5000VA 4500W 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
MINUTEMAN ED6KRT UPS 6000VA 5400W 208-240V 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
Questions about this item
How often will the B00007 battery pack need to be replaced under normal operation?
The B00007 battery module is user-replaceable and typically lasts three to five years depending on discharge cycles and ambient temperature.
What limits continuous output when the UPS runs at full 6000 VA load for extended periods?
The 1.0 power factor rating means the 6000 VA unit delivers 6000 watts continuously; the first limit reached is the 6000 watt thermal ceiling of the double-conversion inverter.
How much heat does the 237 lb cabinet reject when it powers a full load all day?
At full load the double-conversion topology dissipates several hundred watts as heat, requiring adequate room ventilation to keep internal temperatures within design limits.
More in Uninterruptible Power Supplies (UPS)
Similar items
CyberPower CP1500PFCLCD UPS 1500VA 1000W 12 Outlets Sine
- 120 V
- 88-144 Vac
Vertiv Liebert GXT5-3000LVRT2UXL UPS 3000VA 2700W 120V 2U
- 120 V
- 60-150 V
Tripp Lite SMART1500LCDXL 1500VA 900W UPS
- 120 V
- 110–120 V
Tripp Lite SU3000RTXLCD2UN 3000VA 2700W 120V UPS
- 120 V
- NEMA L5-30P
APC BE600M1 Back-UPS 600VA UPS 120V 7 Outlets USB Charging
- 120 V
- 92–139 V
Eaton 9SX3000HW 3000 VA 120 V Hardwired Tower UPS
- 100 V AC - 138 V AC
- 100 V AC, 110 V AC,…