APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Metered 208 V three-phase PDU delivers 44 locking outlets and real-time power monitoring in a 0U vertical form factor
The APC AP8865 is a 0U vertical power distribution unit built for three-phase 208V environments. It delivers 44 outlets — 36 IEC C13, six IEC C19, and two NEMA 5-20R — from a single NEMA L21-30P input rated at 8.6 kW. Data centre managers use it to monitor real-time power draw and balance loads across phases.
The 0U form factor mounts in the zero-U space at the rear of a standard rack without consuming rack units. A 5.9 ft cord reaches side or top power feeds, while locking IEC receptacles prevent accidental disconnects during cable management. Installers must verify the facility provides a 30 A three-phase service with an L21-30P receptacle and 24 A derated capacity.
Metering circuitry reports per-phase current, voltage, and kilowatt-hours through Web, SNMP, and Telnet interfaces without interrupting output. User-defined alarm thresholds trigger local and remote alerts before the 24 A derated limit is reached. Operating range spans -5 °C to 45 °C and 5 % to 95 % humidity, so thermal drift does not degrade measurement accuracy during extended runs.
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
| Product | |
|---|---|
| Brand name | APC |
| Model name | AP8865 |
| Product type | Metered |
| Storage | |
| Storage elevation | 0–15000 m |
| Power | |
| Supply voltage | 208 V 3PH |
| Input line frequency | 50/60 Hz |
| Regulatory derated input current | 24A |
| Input connection | NEMA L21-30P |
| Voltage output | 208 V |
| Output outlets | 36 x IEC 320 C13 (6) IEC 320 C19 (2) NEMA 5-20R |
| Overload protection | Yes |
| Size & build | |
| Rack height | 0U |
| Cord length | 6 ft (1.83 m) |
| Product dimensions | 70.51 in × 2.2 in × 1.81 in |
| Product weight | 16.67 lb (7.56 kg) |
| Shipping weight | 9.18 kg |
| Package size | 2000 × 162 × 107 mm |
| Environment & compliance | |
| Certified standards | CSA C22.2 No. 60950,UL 60950-1 |
| RoHS compliance | Yes |
| Operating conditions | -5–45 ºC |
| Operating humidity | 5–95% |
| Operating altitude | 0–3000 m |
| Storage temperature range | -25–65 ºC |
| Storage relative humidity | 5–95% |
Check the local display for real-time current readings per phase and confirm they match the expected load; then log into the Web, SNMP or Telnet interface to see the same values reported remotely.
The PDU includes the 5.9 ft NEMA L21-30P input cord and locking IEC C13/C19 receptacles; IEC C13/C19 power cords for servers and an optional temperature/humidity sensor are not included.
This model provides thirty-six C13 outlets for standard servers, six C19 outlets for higher-current equipment, and two NEMA 5-20R outlets for ancillary gear.
More in Rackmount PDUs
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?