APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
A 0U metered rack PDU delivering 230V from a 400V three-phase 32A feed, with 30 C13 and 12 C19 outlets and a local current display for overload prevention
This metered power distribution unit mounts in a 0U form factor and accepts 400V three-phase input at up to 32A through an IEC 309 3P+N+E connector. It delivers 230V output to thirty C13 and twelve C19 locking receptacles. A local digital display shows aggregate current draw so installers can avoid overloads in high-density environments.
The IEC 309 32A 3P+N+E plug restricts the unit to supplies that provide 400V three-phase power at 50 or 60 Hz with a matching socket. Maximum input current is capped at 32A, so total connected load must stay within that limit. Operating temperature range is 0 to 55 °C with humidity from 5 to 95 % non-condensing, and altitude up to 3000 m.
The combination of thirty C13 and twelve C19 receptacles determines whether the PDU matches the cable ends on your servers and network gear. Both outlet types are IEC 320 locking style to prevent accidental disconnection. If your equipment uses different plug types or requires a different outlet count, this unit will not suit the rack.
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
| Product | |
|---|---|
| Brand name | APC |
| Model name | AP8886 |
| Product type | Metered |
| Storage | |
| Storage elevation | 0–15000 m |
| Power | |
| Supply voltage | 400 V 3PH |
| Input line frequency | 50/60 Hz |
| Input current rating | 32A |
| Input connection | IEC 309 32A 3P+N+E |
| Voltage output | 230 V |
| Output outlets | (30) IEC 320 C13 (12) IEC 320 C19 |
| Overload protection | Yes |
| Size & build | |
| Rack height | 0U |
| Product dimensions | 72 in × 2.2 in × 2 in (H × W × D) |
| Product weight | 19.18 lb (8.7 kg) |
| Shipping weight | 11.52 kg |
| Package size | 2050 × 170 × 112 mm |
| Environment & compliance | |
| Certified standards | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Class A, ICES-003, VCCI Class A, VDE |
| RoHS compliance | Yes |
| Operating conditions | 0–55 °C |
| Operating humidity | 5–95% |
| Operating altitude | 0–3000 m |
| Storage temperature range | -25–65 ºC |
| Storage relative humidity | 5–95% |
This unit provides 30 C13 outlets for standard server cords and 12 C19 outlets for high-power equipment, letting you match the mix to your devices.
The 32A three-phase input at 400V supports up to 22kW total, with the metered display showing real-time aggregate current so you stay below the 32A limit per phase.
It requires a matching 32A three-phase supply with neutral and earth, common in European data centres, and fixes the maximum input current at 32A per phase.
More in Rackmount PDUs
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?