CyberPower PDU42014 Switched PDU 100-240 VAC 20 A 10 ft IEC-320 C20 SNMP
Distributes 100-240 VAC power with switched outlet control, 20 A rating, 10 ft cord, IEC-320 C20 input and SNMP monitoring
- Switched outlets enable remote power cycling via SNMP
- 10 ft cord provides flexible rack placement with straight C20 plug
- 20 A rating supports high-density equipment loads
- Single-phase 100-240 VAC input works worldwide without configuration
- Derated 16 A input ensures safe continuous operation on standard circuits
Single-phase switched PDU
The CyberPower PDU42014 is a single-phase power distribution unit rated for 100-240 VAC input at 50-60 Hz. It delivers up to 20 A through an IEC-320 C20 inlet with a 10 ft cord. Network management via SNMP allows remote outlet control and monitoring for rack-mounted equipment.
Upgrade from basic power strips
This unit replaces unmanaged power strips when administrators need per-outlet switching and remote reboot capability. The jump is worth it when uptime depends on cycling power to individual servers or network gear without physical access to the rack. Derated input of 16 A provides a safety margin for continuous loads.
IEC-320 C20 inlet constraint
The fixed C20 inlet limits connection to compatible UPS outputs or wall receptacles rated for 20 A. Installations requiring a different plug style or higher current capacity cannot use this unit without an adapter that may void certification. The 10 ft cord length also restricts placement relative to the power source.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $539.99
- Pricier than about 55% of the 640 comparable items (median $458.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Size & build | |
|---|---|
| Shipping weight | 7.71 kg |
| Package size | 272 × 215 × 130 mm |
Questions about this item
What input plug and voltage range does the PDU42014 need to connect to?
The PDU42014 uses an IEC-320 C20 input plug and accepts 100-240 VAC single-phase power at 50-60 Hz.
How do you set up network management on the PDU42014, and what step is often missed?
Connect the unit to your network, then configure the SNMP settings in the web interface; the step often missed is enabling SNMP traps for alert notifications.
When will the PDU42014 need its input cord or plug replaced?
Replace the 10 ft IEC-320 C20 cord if the plug shows heat damage, the cable jacket cracks, or the unit trips its 20 A breaker repeatedly under normal 16 A derated loads.
More in Rackmount PDUs
Similar items
Tripp Lite PDUMH15ATNET PDU 1.4kW 120V 15A 8x 5-15R 2x 5-15P 12ft 1U
- 1U
- 8 LEDs display powe…
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
Tripp Lite PDUMH30HV6 5.8kW Metered PDU 16 C13 2 C19 L6-30P 2U
- 2U
- PDUMH30HV6 5.8 kW S…
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
Vertiv PD2-109 2-Outlet PDU 2×NEMA L14-30R 60A 208V/120V
- Consumer Electronics
- Product Type:PDU, P…