Eaton EVMA4609X-06 3-Phase Managed PDU 208V 42 Outlets 48A 17.3kW 460P9W 6ft 0U
Distributes 208 V three-phase power across 42 outlets with 48 A and 17.3 kW capacity, managed monitoring and 0U vertical mounting
- 208 V three-phase power feeds 42 outlets for dense server racks
- 48 A and 17.3 kW capacity handles heavy compute loads
- 0U vertical mounting preserves every rack unit for equipment
- 6 ft cord with 460P9W connector allows flexible cabinet placement
- Managed monitoring gives real-time visibility into power consumption per outlet
Three-Phase 208V Managed PDU
The Eaton EVMA4609X-06 distributes three-phase 208V power across 42 outlets in a 0U vertical form factor. It supports a total load of 48A and 17.3kW for high-density server cabinets. A 460P9W input connector and 6 ft cord complete the package.
Suited for data centres needing monitored
This unit fits cabinets that can terminate a 460P9W plug and supply 48A three-phase power. Facilities limited to single-phase feeds or lower amperage service cannot use it without electrical upgrades. Buyers without network management infrastructure lose the monitoring benefit.
460P9W input connector decides fit
The 460P9W plug requires a matching receptacle on the facility side. Verify that the upstream circuit provides three-phase 208V at 48A with this exact connector before ordering.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $2,664.99
- Pricier than about 92% of the 640 comparable items (median $458.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
No published specifications for this item yet.
Questions about this item
How do I mount the 0U vertical PDU in a server cabinet, and what is the common mistake?
Secure the unit vertically along the rack’s 0U channel using the supplied brackets; the frequent error is leaving the mounting screws loose, which lets the 6 ft cord pull the PDU out of alignment.
Which component will need replacement first during long-term operation?
The IEC outlet modules are the primary wear items; after thousands of insertion cycles the contact springs fatigue and should be swapped to maintain reliable 208V 3-phase delivery.
What limit appears first when the PDU runs continuously at full load?
The 48A / 17.3kW aggregate rating is the first ceiling; sustained draw at that level trips the internal branch circuit protection before any thermal or connector limit is reached.
More in Rackmount PDUs
Similar items
Eaton EVMAL630X PDU 208V 42 Outlets 24A 5.8kW L6-30 10ft 0U
- Power Distribution…
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
APC APDU11250SW Switched PDU 11.5kW 3Phase 415V 20A 520P6 42 Outlet
- Power Distribution…
- PDUs & Line Conditi…
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
APC APDU9966 Switched PDU 0U 17.3kW 208V 20 C13/C15 12 C19/C21
- Switched