Raritan PX3TS-1876CR 1U 1-Phase 208V 3300VA PDU 8xC13 1xC19 C20 In
A 1U rack-mount PDU delivering 3300 VA at 208 V with eight C13 and one C19 outlets fed by a C20 inlet
- 1-Phase 208V input suits standard rack circuits
- 3300 VA capacity supports dense server loads
- Eight C13 outlets plus one C19 outlet
- IEC 60320 C20 inlet handles 20 A max current
- 1U rack-mount form factor saves vertical space
1U 208 V rack PDU
The Raritan PX3TS-1876CR is a single-phase power distribution unit built for 208 V AC feeds in standard 19-inch racks. It occupies one rack unit and accepts a C20 inlet rated for 20 A maximum input current. Data-centre operators and IT teams use it to branch utility power to servers and network gear.
Nine outlets: eight C13 and one C19
Eight IEC 60320 C13 sockets and one IEC 60320 C19 socket deliver up to 3300 VA total across the strip. The C19 outlet accommodates higher-draw equipment while the C13 bank handles typical server power supplies. The 20 A input limit defines the hard ceiling; sustained loads above that will trip the upstream breaker.
Replaces basic unmetered strips
This unit upgrades from simple power strips that lack inlet monitoring or outlet-level switching. The step up is justified when operators need to track aggregate power draw or plan capacity without adding external meters. It does not suit environments that require per-outlet telemetry or switched control.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $1,439.99
- Pricier than about 87% of the 640 comparable items (median $458.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
No published specifications for this item yet.
Questions about this item
Will the C20 inlet on this PDU connect to my existing 20 A single-phase 208 V UPS output?
Yes, the IEC 60320 C20 input matches a 20 A 208 V single-phase source rated for 50-60 Hz.
How can I confirm the PDU is delivering power to all outlets after installation?
The unit provides local metering that shows real-time current draw across the 8 C13 and 1 C19 receptacles.
Which power cords are included with the PX3TS-1876CR and which must be purchased separately?
The PDU ships with the C20 inlet cord; IEC 60320 C13 and C19 cords for connected equipment are not included.
More in Rackmount PDUs
Similar items
APC AP8965 Switched PDU 208V 30A 3PH 21 C13 3 C19 0U
- 0U
- cUL Listed,FCC Part…
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
APC AP7866A Metered 0U PDU 15-Outlet 16.2kVA 45A 208V 6ft
- 0U
- cUL Listed,CSA C22.…
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
Eaton 9611566 Metered PDU 208V 415/240V 24 Outlets 12 C13 0U
- Metered