STARTECH 12NM8-RACK-MOUNT-PDU 12-Outlet 1U Metered PDU 125V 15A 2.4m Cable
A 1U horizontal rack-mount PDU provides twelve metered outlets with surge protection at 125V 15A via a 2.4m cable
- Product typePDUs & Line Conditioners
- 12 outlets power up to 12 devices
- 15 A metered input tracks real-time load
- 1080 J surge protector guards connected equipment
- 1 U horizontal design fits standard racks
- 4 m cord reaches distant power sources
12-Outlet Metered PDU 1U
This 1U rack-mount power distribution unit provides twelve outlets with a built-in digital meter for real-time load monitoring. It accepts a 120V nominal input and delivers up to 125V output with a 15A maximum total current draw. The 2.4m attached cable ends in a standard North American plug for straightforward installation.
Horizontal Mounting with Surge Protection
Suited for server rooms and network cabinets that need horizontal power distribution and local current visibility. The 1080J surge protector helps guard connected hardware from transient voltage spikes. Not intended for installations requiring vertical mounting, IEC outlet types, or input voltages above 125V.
15A Maximum Current Rating
The unit supports a maximum total current of 15A with a regulatory derated input of 12A for North American codes. This single figure determines whether the PDU can handle your combined equipment load. Verify your rack’s aggregate draw before deployment.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $131.99
- Cheaper than about 81% of the 640 comparable items (median $458.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | StarTech |
| Product type | PDUs & Line Conditioners |
| Size & build | |
| Shipping weight | 2.31 kg |
| Package size | 559 × 559 × 79 mm |
Questions about this item
Does the 12-outlet metered PDU ship with mounting brackets and a 2.4 m power cord, or must any hardware be purchased separately?
The unit includes a 2.4 m power cord and is designed for 1U horizontal rack mounting; no extra mounting hardware or cables are required for standard installation.
When should I select the 125 V 15 A version instead of a lower-amperage model for my rack?
Choose this 125 V 15 A model when your connected equipment draws up to the 12 A derated continuous limit and you need twelve NEMA 5-15R outlets with local metering and 1080 J surge protection.
What does the 15 A rating mean once the PDU is powered in a 120 V North American rack?
The regulatory derated limit is 12 A continuous; the built-in meter displays real-time load so you can keep total draw below that threshold and avoid tripping the branch circuit.
More in Rackmount PDUs
Similar items
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
Valiant Power VP-PDU-30A-1U-8009 PDU 1U 240V 30A 10 C13 2 C19
- 1U
- Standard 19 in





