Tripp Lite PDUB151U PDU Hot Swap Manual Bypass 15A 6 5-15R 2 5-15P
A hot-swap PDU with manual bypass keeps six NEMA 5-15R outlets powered during UPS maintenance via dual NEMA 5-15P inputs
- Product typeBasic
- Hot-swap bypass keeps equipment running during UPS maintenance
- Dual NEMA 5-15P inputs enable manual transfer without power interruption
- Six NEMA 5-15R outlets distribute power to connected devices
- ECO switching feature reduces energy consumption when enabled
- 100-125V 12A single-phase design supports 24/7/365 operation
Hot-swap bypass PDU
The Tripp Lite PDUB151U is a basic power distribution unit that adds a manual bypass switch to a single-phase UPS installation. It lets technicians move connected loads to utility power without shutting them down, so scheduled UPS maintenance or replacement causes no interruption to the attached equipment.
12 A continuous limit
The unit is rated for 12 A continuous output on a 100-125 V supply even though the input plugs are 15 A NEMA 5-15P types. Total connected load must stay at or below 12 A; exceeding that rating will trip the upstream breaker regardless of the plug rating.
Dual-input cord set
Two fixed NEMA 5-15P input cables feed the internal transfer switch, and six NEMA 5-15R outlets distribute power to the rack gear. The cords are not detachable, so rack placement must accommodate both inlet cables reaching their respective wall or UPS receptacles.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $182.99
- Cheaper than about 74% of the 640 comparable items (median $458.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Product type | Basic |
| Size & build | |
| Shipping weight | 3.18 kg |
| Package size | 540 × 210 × 135 mm |
Questions about this item
Should I choose the single-phase 12A version or a three-phase model for my rack?
This PDU is a single-phase 12A unit rated 100-125V with six 5-15R outlets and dual 5-15P inputs; three-phase models are not in this product line.
What does the 15A rating mean once the PDU is installed in my rack?
The 15A plugs feed the unit, but the continuous load is limited to 12A per agency derating, so plan for a maximum of 12A across the six outlets.
How do the NEMA 5-15P inputs and the manual transfer switch work together in practice?
Two 5-15P cords connect to UPS and utility; flipping the front switch to Bypass moves the load to utility power instantly, allowing UPS service with zero downtime.
More in Rackmount PDUs
Similar items
Vertiv VP9567 PDU Basic 15A 120V 14 x 5-15R
- RoHS, UL & c-UL Lis…
- 120 V
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
Vertiv VP9563 PDU 20A 120V 10×5-20R 1U
- RoHS, UL & c-UL Lis…
- Consumer Electronics
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
Synaccess Networks NP-02B Switched PDU, 2 Outlets, 13A, 50/60Hz, RS-232
- 13A
- 50/60 Hz