Tripp Lite PDUMNH20AT1 1.92kW 120V 20A 16 5-15/20R Dual L5-20P 1U PDU
A 1U rack PDU with automatic transfer switching and real-time remote monitoring across 16 NEMA 5-15/20R outlets, dual 12 ft L5-20P inputs and a built-in HTML5 interface
- Rack height1U
- Certified standardsTested to UL62368-1 (USA), CSA (Canada), Class A (Emissions)
- Package includesPDUMNH20AT1 1.92 kW SinglePhase ATS/Monitored PDU Detachable
- Supply voltage120 V
- Input current rating20A
- Cord length12 ft (3.66 m)
- Real-time remote monitoring of voltage, frequency and load via built-in network interface
- Automatic transfer between power sources in under 7 ms maintains continuous operation
- On-site digital ammeter displays current load to help prevent circuit overloads
- Dual 12 ft input cords with NEMA L5-20P plugs connect to independent power feeds
- TAA compliance qualifies the unit for GSA Schedule procurement
1U 1.92kW ATS PDU
This 1U horizontal power distribution unit delivers 1.92kW at 120V with a 20A auto-transfer switch. It suits network IT applications, small computer rooms and equipment racks that need redundant power feeds and real-time load monitoring. Sixteen NEMA 5-15/20R outlets connect servers and networking gear. The unit is tested to UL62368-1, CSA, NOM, RETIE, RoHS and TAA standards.
Dual L5-20P inputs and monitoring
Two 12 ft cords with NEMA L5-20P plugs connect to separate primary and secondary mains circuits, generators or UPS units; two 5-20P adapters are included. The built-in Java-free HTML5 LX Platform interface provides 24/7 remote access to voltage, frequency and load data without client software. A front-panel digital ammeter shows real-time current on site. The ATS switches sources in under 7 ms to maintain continuous operation. A configuration cable, rack-mounting hardware and cable retention kit are supplied.
<7 ms transfer time for continuous uptime
The auto-transfer switch moves load from primary to secondary power in less than 7 ms, preventing equipment restarts during source failures. This speed is the critical specification for environments that cannot tolerate any interruption. Buyers who need longer cord lengths, higher voltage inputs or outlet counts beyond sixteen 5-15/20R receptacles should evaluate other models.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $562.99
- Pricier than about 57% of the 640 comparable items (median $458.99).
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Tripp Lite |
| Model name | PDUMNH20AT1 |
| Product type | Auto-Transfer Switch; Metered |
| Design style | Horizontal |
| Power | |
| Supply voltage | 120 V |
| Input current rating | 20A |
| Voltage output | 100; 120; 127 |
| AC output frequency | 50/60 Hz |
| Output watts (va) | 2.03 kW (127 V), 1.92 kW (120 V), 1.6 kW (100 V) |
| Size & build | |
| Rack height | 1U |
| Cord length | 12 ft (3.66 m) |
| Product dimensions | 1.75 in × 17.5 in × 14.5 in |
| Product weight | 12.2 lb (5.53 kg) |
| Shipping weight | 9.39 kg |
| Package size | 592 × 511 × 137 mm |
| Environment & compliance | |
| Certified standards | Tested to UL62368-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RETIE (Colombia), RoHS Compliant, TAA Compliant |
| RoHS compliance | Yes |
| Operating altitude | 0–3000 m |
| Storage temperature range | -30 °C to 50 °C |
| Storage relative humidity | 5–95% |
Questions about this item
How often should the dual L5-20P input cords be inspected or replaced?
The cords are 12 ft long and rated for 20 A; inspect them annually for wear, damage or loose connections, and replace any cord that shows cracking or overheating.
What is the first limit reached when the PDU runs at full 1.92 kW load continuously?
The 20 A input breaker will trip first if the sustained draw exceeds 1.92 kW at 120 V, protecting the unit and connected equipment.
How much heat does the unit add to the rack when it is passing 1.92 kW all day?
The PDU itself dissipates minimal heat; nearly all 1.92 kW passes through to the 16 outlets, so rack cooling must handle the connected equipment’s load.
More in Rackmount PDUs
Similar items
CyberPower PDU41021 1U Switched PDU 16 Outlets 12 ft 15A NEMA 5-15P
- 1U
- IPv4/v6, SNMPv1/v3,…
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
Tripp Lite PDUMH15ATNET PDU 1.4kW 120V 15A 8x 5-15R 2x 5-15P 12ft 1U
- 1U
- 8 LEDs display powe…
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
Vertiv PD2-109 2-Outlet PDU 2×NEMA L14-30R 60A 208V/120V
- Consumer Electronics
- Product Type:PDU, P…