Vertiv PD2-107 PDU 60A 4×L5-20R 4×5-20R 208V
Distributes 208 V power to eight outlets from a hard-wired 60 A feed for GXT3 and GXT4 UPS units
- Key featuresProduct Type:PDU Input Receptacles:Hard Wire 4-wire (2PH+N+G
- Product weight4.4 lb (2 kg)
- Integrated output distribution for compatible UPS systems
- Hardwire 4-wire input supports 208 V three-phase supply
- Eight total receptacles mix locking and T-slot NEMA types
- Lightweight 4.40 lb chassis simplifies rack installation
Power Distribution Unit for GXT UPS
The Vertiv PD2-107 is a 60 A power distribution unit designed for Liebert GXT3 and GXT4 UPS models rated at 8000 and 10000 VA. It accepts a hard-wired 4-wire 208 V input and delivers power through four NEMA L5-20R and four NEMA 5-20R output receptacles. This unit suits data-centre and network-room installations that require integrated output distribution and maintenance bypass capability.
Sustained Load Distribution
Under continuous operation the PDU passes up to 60 A across its eight outlets without active cooling, relying on the upstream UPS for voltage regulation. The hard-wired input and mixed receptacle array allow balanced loading of both locking and straight-blade connections during extended runtime. Installers should verify that the aggregate draw of connected equipment stays within the 60 A rating to avoid thermal stress on the busbars.
How it compares
Measured against everything we stock in Rackmount PDUs, at today’s prices. Recalculated every night.
- Price $400.99
- Typical for this category: the median of 640 items is $458.99.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Specifications
| Product | |
|---|---|
| Brand name | Liebert |
| Model name | PD2-107 |
| Size & build | |
| Product weight | 4.4 lb (2 kg) |
| Shipping weight | 4.08 kg |
| Package size | 510 × 305 × 230 mm |
Questions about this item
Does the hard-wire 60 A input on the PD2-107 generate noticeable heat or noise when running continuously?
The unit has no fans or moving parts, so it operates silently and adds negligible heat to the rack when distributing power to connected loads.
Which UPS models must I already own for this PD2-107 to work?
It is designed for Liebert GXT3-8000RT208, GXT3-10000RT208, GXT4-8000RT208 and GXT4-10000RT208 UPS systems.
More in Rackmount PDUs
Similar items
APC AP7723 Switched Rackmount PDU 20A 230V 8xC13 1xC19
- cUL Listed, EN 5502…
- Switched
APC AP7894 Metered Zero U Rack 5.7kVA PDU 208V 10ft
- Zero U Rack
- 208 V AC
APC AP7731 Switched Rackmount PDU 30A NEMA L6-30P 8ft
- FCC Part 15 Class A…
- Switched
Tripp Lite PDUMH20AT PDU 1.9 kW 120V 16 Outlets 1U
- 1U
- 16 front panel LEDs…





